Inspirion Inspirion
  • office@inspir-ion.com
  • +385 1 3733-570

TPL_SIDE_BAR

  • Home
  • Electrochemistry
    • Electrochemistry
      • SP-50
      • SP-150
      • SP-200
      • SP-240
      • SP-300
      • VSP
      • VSP-300
      • VMP3
      • VMP-300
    • Battery research
      • MPG-2xx series
      • MPG-2
      • MPG-205
      • BCS-8xx series
      • BCS-805
      • BCS-810
      • BCS-815
      • FlexP 0012
      • FlexP 0160
      • HCV-3048
      • HCP-1005
      • HCP-803
    • Scanning systems
      • SECM150
      • M470 – ic-SECM
      • M470 – ac/dc-SDS
      • M470 - LEIS
      • M470 - SVP
      • M470 - SKP
      • M470 - OSP
    • Material testing
      • MTZ-35
      • HTF-1100
      • ITS
  • MRC Lab
    • Laboratory equipment
    • Analytical equipment
    • Balances
    • Measuring meters
  • Services
  • News
  • About us
  • Contact Us
  • Home
  • Electrochemistry
    • Electrochemistry
      • SP-50
      • SP-150
      • SP-200
      • SP-240
      • SP-300
      • VSP
      • VSP-300
      • VMP3
      • VMP-300
    • Battery research
      • MPG-2xx series
      • MPG-2
      • MPG-205
      • BCS-8xx series
      • BCS-805
      • BCS-810
      • BCS-815
      • FlexP 0012
      • FlexP 0160
      • HCV-3048
      • HCP-1005
      • HCP-803
    • Scanning systems
      • SECM150
      • M470 – ic-SECM
      • M470 – ac/dc-SDS
      • M470 - LEIS
      • M470 - SVP
      • M470 - SKP
      • M470 - OSP
    • Material testing
      • MTZ-35
      • HTF-1100
      • ITS
  • MRC Lab
    • Laboratory equipment
    • Analytical equipment
    • Balances
    • Measuring meters
  • Services
  • News
  • About us
  • Contact Us

Get A Quote...

  1. You are here:  
  2. Home
  3. Electrochemistry
  4. Electrochemistry
  5. Specifications

Specifications

Specifications

  • Current ranging: 10 μA to 800 mA
  • Current resolution: 760 pA (76 fA with low current option)
  • Control voltage: ±10 V
  • Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V
  • Voltage resolution: 5 μV
  • EIS measurement from 10 µHz to 1 MHz
  • Acquisition time: 20 μs
  • Control software: EC-Lab® & EC-Lab® Express
Read more …

Specification

  • Up to 5 independant channels
  • Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V
  • Current ranging from 10 μA up to 1 A
  • Current resolution: 760 pA
  • Low current: 4 ranges 1 μA to 1 nA with a resolution of 76 fA
  • Control voltage: 20 V adjustable
  • Resolution: 5 μV
  • EIS measurement from 10 µHz to 1 MHz
  • Acquisition time: 20 μs
  • Control software: EC-Lab® & EC-Lab® Express
  • Simultaneous EIS measurement on WE and CE electrodes
  • N’Stat mode to perform experiments with several working electrodes
Read more …

Specifications

  • Up to 16 independant channels
  • Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V
  • Current ranging from 10 μA up to 400 mA
  • Current resolution: 760 pA
  • Low current: 4 ranges 1 μA to 1 nA with a resolution of 76 fA
  • Control voltage: 20 V adjustable
  • Resolution: 5 μV
  • EIS measurement from 10 µHz to 1 MHz
  • Acquisition time: 20 μs
  • Control software: EC-Lab® & EC-Lab® Express
  • Simultaneous EIS measurement on WE and CE electrodes*
  • N’Stat mode to perform experiments with several working electrodes
  • Stack measurements up to 30 cells
Read more …

Specifications

  • Up to 16 independent channels
  • Compliance: ±12 V up to ±49 V with booster
  • Control voltage: ±10 V up to ±48 V with booster
  • Potential resolution: 1 µV
  • EIS measurement: 10 μHz – 3 MHz (1%, 1°), 10 μHz – 7 MHz (3%, 3°)
  • Current ranges: 1 A to 10 nA (standard)
  • Maximum current: ±500 mA (standard)
  • Up to 150 A with boosters in parallel
  • Current resolution: 760 fA (standard)
  • Low current: 6 ranges from 100 nA to 1 pA with resolution to 76 aA
  • Floating mode
  • Analog filtering
  • Calibration board
  • Full stability control mode (9 bandwidths)
Read more …

Specifications

  • Compliance: ±12 V
  • Control voltage: ±10 V
  • EIS measurement: 3 MHz (1%, 1°) 7 MHz (3%, 3°)
  • Current ranges: 500 mA to 1 µA (10 nA with gain)
  • Current resolution 760 fA (standard board)
  • Low current: 6 ranges from 100 nA to 1 pA with resolution to 76 aA
  • Floating mode
  • Analog filtering
  • Calibration board
  • Full stability control mode (9 bandwidths)
Read more …

Specifications

  • Up to 6 channels
  • Compliance: ±12 V up to ±49 V with booster
  • Control voltage: ±10 V up to ±48 V with booster
  • Potential resolution: 1 µV
  • EIS measurement: 10 μHz – 3 MHz (1%, 1°), 10 μHz – 7 MHz (3%, 3°)
  • Current ranges: 1 A to 10 nA (standard)
  • Maximum current: ±500 mA (standard)
  • Up to 40 A with boosters in parallel
  • Current resolution: 760 fA (standard)
  • Low current: 6 ranges from 100 nA to 1 pA with resolution to 76 aA
  • Floating mode
  • Analog filtering
  • Calibration board
  • Full stability control mode (9 bandwidths)
Read more …
Page 2 of 3
  • Start
  • Prev
  • 1
  • 2
  • 3
  • Next
  • End
 

Inpsirion logo AD2

About us

  • About us
  • Our story
  • News and events
  • Contact us

Our products

  • Electrochemistry
  • Battery testing
  • Scanning systems
  • Material research
  • Fuel cells
  • MRC Lab equipment

Our Services

  • Electrochemistry
  • Batteries
  • Pharma
  • Advanced materials
 

Copyright © 2018 Inspirion. All Rights Reserved.