Specifications Current ranging: 10 μA to 800 mA Current resolution: 760 pA (76 fA with low current option) Control voltage: ±10 V Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V Voltage resolution: 5 μV EIS measurement from 10 µHz to 1 MHz Acquisition time: 20 μs Control software: EC-Lab® & EC-Lab® Express Read more …
Specification Up to 5 independant channels Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V Current ranging from 10 μA up to 1 A Current resolution: 760 pA Low current: 4 ranges 1 μA to 1 nA with a resolution of 76 fA Control voltage: 20 V adjustable Resolution: 5 μV EIS measurement from 10 µHz to 1 MHz Acquisition time: 20 μs Control software: EC-Lab® & EC-Lab® Express Simultaneous EIS measurement on WE and CE electrodes N’Stat mode to perform experiments with several working electrodes Read more …
Specifications Up to 16 independant channels Compliance: 20 V range adjustable from [-20;0] V to [0;+20] V Current ranging from 10 μA up to 400 mA Current resolution: 760 pA Low current: 4 ranges 1 μA to 1 nA with a resolution of 76 fA Control voltage: 20 V adjustable Resolution: 5 μV EIS measurement from 10 µHz to 1 MHz Acquisition time: 20 μs Control software: EC-Lab® & EC-Lab® Express Simultaneous EIS measurement on WE and CE electrodes* N’Stat mode to perform experiments with several working electrodes Stack measurements up to 30 cells Read more …
Specifications Up to 16 independent channels Compliance: ±12 V up to ±49 V with booster Control voltage: ±10 V up to ±48 V with booster Potential resolution: 1 µV EIS measurement: 10 μHz – 3 MHz (1%, 1°), 10 μHz – 7 MHz (3%, 3°) Current ranges: 1 A to 10 nA (standard) Maximum current: ±500 mA (standard) Up to 150 A with boosters in parallel Current resolution: 760 fA (standard) Low current: 6 ranges from 100 nA to 1 pA with resolution to 76 aA Floating mode Analog filtering Calibration board Full stability control mode (9 bandwidths) Read more …
Specifications Compliance: ±12 V Control voltage: ±10 V EIS measurement: 3 MHz (1%, 1°) 7 MHz (3%, 3°) Current ranges: 500 mA to 1 µA (10 nA with gain) Current resolution 760 fA (standard board) Low current: 6 ranges from 100 nA to 1 pA with resolution to 76 aA Floating mode Analog filtering Calibration board Full stability control mode (9 bandwidths) Read more …
Specifications Up to 6 channels Compliance: ±12 V up to ±49 V with booster Control voltage: ±10 V up to ±48 V with booster Potential resolution: 1 µV EIS measurement: 10 μHz – 3 MHz (1%, 1°), 10 μHz – 7 MHz (3%, 3°) Current ranges: 1 A to 10 nA (standard) Maximum current: ±500 mA (standard) Up to 40 A with boosters in parallel Current resolution: 760 fA (standard) Low current: 6 ranges from 100 nA to 1 pA with resolution to 76 aA Floating mode Analog filtering Calibration board Full stability control mode (9 bandwidths) Read more …